| Project |
Hydrocracker Pilot Plant Unit (Fixed Bed) |
Client: Indian Oil Corporation Limited, Faridabad
|
‹ Back |
| |
| Purpose: |
 |
Hydrocracking of VGO for catalyst evaluation |
| Plant Details: |
 |
Operating Temperature: 450oC |
 |
 |
Operating Pressure: 200 bar.g |
 |
 |
VGO feed with recycle feed module |
 |
 |
Unit included: total 2 tubular fixed bed reactors (MOC:RA330) of |
| |
400 ml catalyst capacity, such that the reactors operate in series, |
| |
parallel or independently |
 |
 |
Unit also included separator section with 2 phase separator, Caustic |
| |
scrubber & recycle gas compressor, liquid stripping with stripper, |
| |
packed heated atmospheric & vacuum column, cast in Bronze block furnace and LPG recovery system. |
 |
 |
PC-PLC based control System |
 |
 |
Year of completion: 2005 |
|
|
|
|